Air flow measurement grid
Project-specific grid that measures gas flow rate and velocity in ducts with low pressure loss
LAMTEC
- 2 … 40 m/s
- -20 … +400 °C
- Stainless steel
LAMTEC measuring grids determine the volume flow, mass flow and velocity of gaseous media. Their main use is flow measurement in ducts, above all of combustion air supplied to firing systems; with optional materials they can also measure flue gas flow. The medium must be a non-aggressive, non-explosive gas of known density. The grid geometry is adapted to each customer's conditions while keeping pressure loss low, and the LAMTEC calculation tool sizes LAMTEC transmitters or the customer's own transmitters for the given plant data.
Measurement is based on Bernoulli's equation. Parallel tubes with closed ends span the duct cross-section at right angles to the flow and form an open grid: openings in some tubes pick up the total pressure, while the others pick up the reference pressure. Each pressure is gathered in its own collecting tube and connection; the difference between them, the dynamic pressure, indicates flow velocity, and with a known duct diameter the volume flow follows from the square root of the reading. Since the whole cross-section is measured, poor flow profiles can be handled too; flow velocity has to be within 2 to 40 m/s.
The grid is fully welded from stainless steel; round versions come with or without flanges, while rectangular versions usually need none. It can be flanged, welded in or clamped onto a Jacob pipe system, and the differential pressure transmitter connects through a G1/4" threaded socket. Compared with orifice plates or venturi nozzles, pressure loss is very low and the straight inlet and outlet runs can be much shorter, so the grid is easy to retrofit in existing plants. In clean air it needs no maintenance; plants with heavy dust loads should allow access for cleaning, and the grid must not be used where sticky particles are carried in the air.
Air flow measurement grid
- Project-specific design with very low pressure loss; the loss is calculated for each order and stated in the order documents
- Short straight inlet runs: between 1 and 6 duct diameters (D), depending on the obstacle type and tolerance
- Measurement across the full cross-section, so unfavourable flow profiles can be handled
- Medium temperatures up to 400 °C; wider ranges on request
- No maintenance in clean media; backflushing for particle-laden media (optional)
- Works with any commercial differential pressure transmitter with a ±0…10 mbar range
- Design software calculates the plant-specific differential pressure curve and, with a known gas temperature, the standard volume flow as well
Air flow measurement grid
Purging unit
Optional unit that enables measurement in particle-laden media. LAMTEC's sample configuration combines a round measuring grid, a transmitter and a purging unit.
Key specifications
| Specification | Mass Flow Measurement Grid |
|---|---|
| Flow velocity | 2 … 40 m/s |
| Medium temperature | -20 … +400 °C (wider range on request) |
| System pressure | -0.5 … +0.5 bar |
| Accuracy (of measured value) | ≤ 1 % (compared on test rig) · ≤ 2 % (calibrated on site) · ≤ 5 % (calculated) |
| Material | Stainless steel (fully welded construction) |
| Design | Round (with or without flanges) · rectangular |
| Installation | Flange connection · welded-in · clamp connection for Jacob pipe |
Accessories
- Differential pressure transmitters with ranges of 0…250, 0…1000, 0…3000 or 0…7000 Pa; output 4…20 mA, 0…20 mA or 0…10 V depending on design
- Differential pressure transmitter with pressure and temperature compensation
More products in this group
CMS combustion management system
Modular burner and plant control that scales from small industrial burners to large installations
- SIL3 · CE · UL
- ≤ 10 actuators
- Modbus TCP
BT300 burner control unit
Compact burner-mounted unit that pairs fuel-air ratio control with a burner sequencer
- ≤ 3 actuators
- Burner-mounted
- SIL3 (BT331, BT341)
MCC-BC400 burner sequencer
Configurable burner sequencer for gas-fired, oil-fired and dual-fuel burners
- SIL3 · CE · UL
- Gas · Oil · Dual fuel
- Modbus TCP
BC300 gas burner sequencer
Burner sequencer for industrial gas burners in thermal process plants, approved for intermittent and continuous operation
- SIL3 · CE
- Intermittent · Continuous
- High-temperature operation > 750 °C
Let's choose the right product for your project together
Tell us about your plant and what you need, and our engineers will recommend the right solution.