Deluxia Palace, Barbaros Mah. Mor Sümbül Sok. No:5A/88 Kat:3, Ataşehir / İstanbul info@uztherm.com

LT3-Ex explosion-protected measuring system

O₂ and COe measurement in flue gas for Ex zones 1 and 2 with LS2-Ex and KS1D-Ex probes

Flue gas measurement

LAMTEC · LT3-Ex

  • O₂ + COe
  • Ex zones 1 and 2
  • SIL1 · SIL2 (2 × LT3-Ex)

LT3-Ex is the version of the LAMTEC lambda transmitter designed for hazardous areas; with an LS2-Ex or KS1D-Ex probe it forms a microprocessor-based measuring system. The transmitter's type of protection is flameproof enclosure (Ex d) or, alternatively, increased safety (Ex eb), so the complete system of transmitter and probes can be used in Ex zones 1 and 2. With the KS1D-Ex probe it measures O₂ in the excess-air range (λ > 1) and, at the same time, COe, the sum signal of oxidisable components such as CO/H₂; with the LS2-Ex probe it measures oxygen only.

The unit is operated with a magnetic pen while the housing stays closed, so no special measures are needed while it runs in Ex zones 1 and 2. The magnetic panel shows O₂ and CO readings, probe and fuel information, warnings and faults, and is used for settings such as measurement adjustment, filter time, analogue output and probe exchange. The standard version is SIL1 certified to DIN EN 61508, and the configuration with two transmitters is SIL2 certified to the same standard.

With the GED FLEX gas extraction device, the probes measure in flue gas at up to 1400 °C, depending on the device material. KS1D-Ex covers a COe range of 0…1000 ppm, or 0…10 000 ppm on request. The system is used with light fuel oil, natural gas and coal firing, and other fuels are possible on request. For longer distances between LT3-Ex and the probe, there is a PCB-Ex probe connection box for Ex zones 1 and 2, plus an ATEX connecting and extension cable that links the probe to the box.

LT3-Ex explosion-protected measuring system
LT3-Ex explosion-protected measuring system 1LT3-Ex explosion-protected measuring system 2
Benefits

LT3-Ex explosion-protected measuring system

  • O₂ measurement with the LS2-Ex probe; O₂ and COe measurement with the KS1D-Ex probe
  • The complete system of transmitter and probes can be used in Ex zones 1 and 2
  • Operation with a magnetic pen through the closed housing; no special measures needed while running in Ex zones 1 and 2
  • Robust, compact housing
  • SIL1 to DIN EN 61508 in the standard version
  • SIL2 to DIN EN 61508 in the configuration with two transmitters
  • COe reading unaffected by infiltrated air; measurement directly in moist flue gas without gas conditioning
  • Field-proven design that needs little maintenance
Modules

LT3-Ex explosion-protected measuring system

LS2-Ex probe

Lambda probe that measures oxygen in Ex zones 1 and 2; IP65, ambient temperature in the hazardous area -20…+60 °C. It is used with the GED FLEX gas extraction device, whose immersion depth is adjustable.

KS1D-Ex combination probe

Combination probe for Ex zones 1 and 2 with a heated ZrO₂ cell carrying O₂, COe and reference electrodes; it measures O₂ together with COe, the sum of oxidisable components such as CO/H₂. It carries the same Ex markings as LS2-Ex and is used with GED FLEX. COe accuracy is ±25 % of reading, not better than ±20 ppm.

LT3-Ex

Key specifications

General data
SpecificationLT3-Ex
Measuring rangeO₂: 0 … 21 % · COe (KS1D-Ex): 0 … 1000 ppm (0 … 10 000 ppm on request)
Measuring accuracy (O₂)±5 % (of reading, not better than ±0.3 vol.%)
Response time (t90)O₂: < 9 s · COe: < 13 s
Explosion protection (Ex)Ex zones 1 and 2 · II 2G Ex d IIC T5 Gb · II 2G Ex db eb IIC
Ambient temperature-20 … +55 °C
Safety integrity levelSIL1 · SIL2 (2 × LT3-Ex)
Probe data
SpecificationLS2-Ex / KS1D-Ex
Max. flue gas temperature≤ 1400 °C (GED FLEX, material-dependent)
Degree of protectionIP65
Explosion protection (Ex)Ex zones 1 and 2 · II 2G Ex db (IIB+H2) T4 Gb · II 2D Ex tb IIIC T135 °C Db
Ambient temperature-20 … +60 °C

Full technical data: data sheet(opens in a new tab)

Approvals and standards

  • CE declaration of conformity (2014/35/EU, 2014/30/EU, 2011/65/EU)
  • EU type examination certificate — DIN EN 16340 (with KS1D-Ex only)
  • DIN EN 60730-1
  • Ex certificate LT3-Ex (Ex zones 1 and 2) — II 2G Ex d IIC T5 Gb, II 2G Ex db eb IIC
  • Ex certificate LS2-Ex, KS1D-Ex (Ex zones 1 and 2) — II 2G Ex db (IIB+H2) T4 Gb, II 2D Ex tb IIIC T135 °C Db
  • SIL1 — DIN EN 61508
  • SIL2 — DIN EN 61508 (configuration with two transmitters)

Accessories

  • Analogue current and voltage output module (0/4…20 mA, 0/2…10 V)
  • Digital output module
  • PROFIBUS DP module
  • Efficiency calculation module
  • PCB-Ex probe connection box (Ex zones 1 and 2) for longer distances between LT3-Ex and the probe; II 2GD Ex e IIC T5 Gb, IP66, -20…+55 °C
  • ATEX connecting and extension cable that links an LS2-Ex or KS1D-Ex probe to the PCB-Ex box (Ex zones 1 and 2)

Documents

Let's choose the right product for your project together

Tell us about your plant and what you need, and our engineers will recommend the right solution.