LT2 measuring system

Versatile, modular system for O₂ and CO/H₂ measurement in flue gas with LS2 and KS1D probes

Flue gas measurement

LAMTEC · LT2

  • O₂ + COe
  • LS2/KS1D: ECO · BF · KAF · Ex
  • SIL1 (KS1D, special configuration)

LT2 is a microprocessor-based measuring system that uses the LAMTEC lambda transmitter with an LS2 lambda probe or a KS1D combination probe, and it is the versatile alternative to LT3. With LS2 it measures oxygen only; with KS1D it measures O₂ in the flue gas of combustion plants and, at the same time, COe, the sum signal of oxidisable components such as CO and H₂. Every LS2 and KS1D probe, including the ECO, BF, KAF and Ex types, can be connected to LT2.

As the system is modular, probe, gas extraction device and options are combined to suit each measuring task. Optionally, LT2 also controls probe purging and automatic calibration. With the GED FLEX gas extraction device, measurement is possible in flue gas at up to 1400 °C depending on the device material; with KAF probes, in gas carrying up to 2000 mg/Nm³ of dust. KS1D probes cover a COe range of 0…1000 ppm, or 0…10 000 ppm on request.

For Ex zones 1 and 2, LT2 is also offered in an EExd housing with ATEX and IECEx marking and works with Ex-type LS2/KS1D probes. As a special configuration, LT2 can be supplied with SIL1 certification to DIN EN 61508 covering safe measurement and limit value output when used with the KS1D probe. The transmitter runs on 230 V or 115 V AC and talks directly to LAMTEC combustion management systems over LSB; PROFIBUS DP and Modbus RTU connections are optional.

LT2 measuring system
LT2 measuring system 1LT2 measuring system 2LT2 measuring system 3LT2 measuring system 4LT2 measuring system 5
Benefits

LT2 measuring system

  • O₂ measurement with the LS2 probe; O₂ and COe measurement with the KS1D probe
  • Works with every LS2 and KS1D probe, including the ECO, BF, KAF and Ex types
  • Probe purging and automatic calibration control can be added as options
  • COe reading unaffected by infiltrated air; in-situ measurement in moist flue gas without gas conditioning
  • EExd housing option with ATEX and IECEx marking for Ex zones 1 and 2
  • SIL1 to DIN EN 61508 in a special configuration with KS1D
  • Field-proven design that needs little maintenance
  • Extensions such as a PID O₂ controller, limit value curves, efficiency calculation and a reference air pump
Modules

LT2 measuring system

LS2 probe

Lambda probe that measures the oxygen in the flue gas directly. With LT2 it can be used as the ECO type (≤ 300 °C, IP42), as the BF type with a GED BASE or GED FLEX gas extraction device, as the KAF type with purging and filter fleece for high dust loads, and as the Ex type for Ex zones 1 and 2. On the KAF type, reference air comes from an instrument air connection on site.

KS1D combination probe

Combination probe with a heated zirconium dioxide (ZrO₂) cell and three electrodes: O₂, COe and reference. It measures O₂ together with COe, the sum of oxidisable components such as CO and H₂; COe accuracy is ±25 % of reading, not better than ±20 ppm. Like LS2, it comes in ECO, BF and KAF types and as an Ex type for Ex zones 1 and 2.

LT2

Key specifications

General data
SpecificationLT2
Measuring rangeO₂: 0 … 21 % · COe (KS1D): 0 … 1000 ppm (0 … 10 000 ppm on request)
Measuring accuracy (O₂)±5 % (of reading, not better than ±0.3 vol.%)
Response time (t90)O₂: < 9 s · COe: < 13 s (LS2/KS1D ECO, BF, Ex)
Supply voltage230 V AC / 115 V AC
InterfacesLSB · PROFIBUS DP, Modbus RTU (optional)
Safety integrity levelSIL1 (KS1D, special configuration)
Probe data
SpecificationLS2/KS1D-Ex + GED FLEXLS2/KS1D ECO + GED ECOLS2/KS1D-BF + GED BASELS2/KS1D-BF + GED FLEXLS2/KS1D-KAF
Max. flue gas temperature≤ 1400 °C (material-dependent)≤ 300 °C≤ 550 °C≤ 1400 °C (material-dependent)≤ 450 °C
Dust concentration≤ 1000 mg/Nm³ (with purging)≤ 100 mg/Nm³≤ 200 mg/Nm³≤ 1000 mg/Nm³ (with purging)≤ 2000 mg/Nm³
Degree of protectionIP65IP42IP65IP65IP65
Explosion protection (Ex)Ex zones 1 and 2 · II 2G Ex db (IIB+H2) T4 Gb · II 2D Ex tb IIIC T135 °C Db————

Full technical data: data sheet(opens in a new tab)

Approvals and standards

  • CE declaration of conformity (2014/35/EU, 2014/30/EU, 2011/65/EU)
  • DIN EN 61326-1
  • DIN EN 61010-1
  • SIL1 — DIN EN 61508 (special configuration with KS1D)
  • ATEX / IECEx — II 2G Ex d IIB+H2 T5 Gb, II 2D Ex tb IIIC T100 °C Db (LT2 EExd housing, Ex zones 1 and 2)

Accessories

  • 4 analogue outputs, current (0/4…20 mA) or voltage (0…10 V); 1 or 2 standard, the rest optional; with KS1D, floating design only
  • 7 configurable digital outputs; relay outputs via the 657R0857 relay module, max. 230 V AC / 4 A or max. 48 V DC / 3 A
  • 4 analogue inputs (1 standard, 3 optional): 0/4…20 mA signal, Pt100, 1…5 kΩ potentiometer, pressure sensor or CO/H₂ signal
  • PC remote display software (657R1101); the RS 232 connection works only with this software
  • Integrated PID O₂ controller; limit values and limit curves that depend on load and fuel
  • Flue gas and intake air temperature measurement, combustion efficiency calculation and fuel-specific CO₂ calculation (657R0910)
  • Reference air pump 657R1060 (230 V AC, 115 V AC, or 230 V AC in a stainless steel housing); LT2 is also offered with the pump in its wall housing
  • Fully automatic calibration system 657R0940 for BF, Ex and KAF probe types; 24 V DC from the LT2 relay module, IP66, no explosion protection approval
  • Purge unit: 657R0934 for GED FLEX (min. 6 bar, no Ex approval) or 650R2080 for the KAF pre-filter; LT2 needs the 657R0857 relay module
  • LT2 EExd housing, Ex zones 1 and 2: window, control buttons, main switch, IP66, -20…+60 °C; requires the LT2 EEx configuration