WB-E electric water bath heater
Heater that warms natural gas, crude oil and process fluids indirectly through an electrically heated water bath
TSB Energy · WB-E
- ≤ 8 000 000 kcal/h
- Water bath ≤ 87 °C
- API 12K · ASME VIII-1
- No burner or flue needed
In the WB-E, a bank of electric heaters at the bottom of an insulated shell heats water or another bath liquid. The liquid circulates by natural convection and passes its heat to process coils in the upper part of the shell and on to the fluid flowing through them, so gas is heated without a high-pressure vessel. TSB builds the heater for up to 8 000 000 kcal/h (32 000 000 Btu/h) of electrically supplied heat. A bath temperature of 87 °C (190 °F) is regarded as the operating maximum, and lower temperatures are preferred where inlet and outlet conditions allow.
When pressure is reduced at gas wellheads and in pipelines, the Joule-Thomson effect cools the gas by roughly 5 °C for every 1000 kPa of pressure drop, so the heater is placed ahead of pressure reduction to prevent ice crystals and hydrates. Other duties include lowering crude oil viscosity and keeping it above the paraffin pour point, heating well fluids before separators, preventing sulphur deposits from high-sulphur gas, vaporising LPG and LNG, and heating regeneration gas, amine and TEG reboilers and chemicals. It is intended for oil fields, offshore platforms, refineries and LNG and LPG plants.
A temperature controller with SSR drives holds the bath at its set value, an expansion tank on top absorbs the liquid's volume changes, and coil sections can be taken out of the shell for inspection and repair. Coil connections, flanges and valves are rated to ANSI/ASME B16.5 or API 6A. A safety alarm unit detects high temperature as well as high and low pressure and provides fail-safe relay outputs. Design follows API 12K, ASME Section VIII Div. 1, PED 2014/68/EU and DIN 4754, or ANSI B31.1.
WB-E electric water bath heater
- Non-pressurised bath: gas is heated without a high-pressure vessel
- Running at the lowest bath temperature that still prevents hydrates saves energy and raises downstream liquid recovery
- Flow monitoring built into every heater, staged temperature protection and emergency shutdown
- No fuel is burned: no burner or flue and zero emissions at the point of use
- Coil sections removable from the shell for inspection and repair
- Fully integrated solution with circulation pumps, system valves and piping
- Remote monitoring via Modbus, Modbus TCP/IP and Profinet
Key specifications
| Specification | WB-E |
|---|---|
| Thermal capacity | ≤ 8 000 000 kcal/h (≤ 32 000 000 Btu/h) |
| Operating temperature | Water bath ≤ 87 °C (190 °F) |
| Flange connection | ANSI/ASME B16.5 · API 6A |
| Heater watt density | 70 … 75 W/in² |
| Overvoltage tolerance | ≤ 10 % |
| Interfaces | Modbus · Modbus TCP/IP · Profinet |
Approvals and standards
- API 12K — indirect-type oil-field heaters (design and manufacture)
- ASME VIII Div. 1 — pressure vessels (design and manufacture)
- ANSI B31.1 — power piping (design and manufacture)
- DIN 4754 — heat transfer oil systems (design and manufacture)
- PED 2014/68/EU — Pressure Equipment Directive (design and manufacture)
- TRD — German technical rules for steam boilers
Accessories
- Circulation pumps
- Valves and control equipment for the system
- Piping systems
- PLC supporting communication protocols such as Modbus and Profibus
More products in this group
Three-pass steam boiler
Scotch-type fire-tube boiler for industry: up to 30 000 kg/h of steam at pressures up to 25 bar
- ≤ 30 000 kg/h
- ≤ 21 000 kW
- ≤ 25 bar
Water-tube steam boiler
Low-water-content boiler that raises steam in 10–15 minutes: up to 80 000 kg/h of steam at up to 160 bar
- ≤ 80 000 kg/h
- ≤ 160 bar
- Efficiency ≥ 95 %
Mobile steam boiler room
Complete steam boiler house in a 20 ft or 40 ft ISO container, factory-tested and ready to connect
- ≤ 6000 kg/h
- ≤ 16 bar
- ISO 20 ft / 40 ft
Liquid and gas-fired thermal oil heater
Forced-circulation coil heater that brings thermal oil up to 420 °C in a closed loop (special equipment above 300 °C)
- ≤ 420 °C (special equipment > 300 °C)
- ≤ 12 000 kW
- ≤ 25 bar
Let's choose the right product for your project together
Tell us about your plant and what you need, and our engineers will recommend the right solution.