Deluxia Palace, Barbaros Mah. Mor Sümbül Sok. No:5A/88 Kat:3, Ataşehir / İstanbul info@uztherm.com

Composite autoclave

Electrically or thermal-oil heated autoclave that cures vacuum-bagged thermoset composite parts under heat and pressure

Autoclaves

TSB Energy

  • 1 … 70 bar (per project)
  • Ø ≤ 5500 mm · L ≤ 61 m
  • Temperature accuracy ±1 °C
  • NADCAP · AMS2750 · Boeing D6-49327

The composite autoclave cures vacuum-bagged thermoset parts by pressurising the vessel from outside throughout a heated cure cycle. The pressure cuts resin voids and helps reach the intended resin-to-fibre ratio, giving light, strong and dimensionally stable parts. TSB Energy builds these autoclaves for 1–70 bar, with diameters of up to 5500 mm and lengths of up to 61 m, heated electrically or by thermal oil. Aerospace, defence, automotive, marine and motorsport manufacturers are the main users.

A proprietary baffle design drives turbulent air from front to back, so the parts heat quickly and evenly and the temperature is held to ±1 °C, while sensors on the parts track part and air temperature. Vacuum is monitored bag by bag, leak tests run automatically before and during the cycle and are kept as reports, and a 6-step integrity check precedes every start. For cooling, heat moves from an inner to an outer oil exchanger through 3-way proportional valves with 0.1 % resolution, so the specified cooling curve is followed. The vessel is pressurised with air or nitrogen, and nitrogen can be recovered with TSB's compressor partners.

The autoclave is designed to PED 2014/68/EU, ASME VIII Div. 1, EAC (GOST), EN 13445 and AD 2000-Merkblatt, horizontal or vertical, with one or two doors, and meets NADCAP, AMS2750, Airbus and Boeing D6-49327 requirements. The shell is P355GH/P460NL plate, and the highly loaded closure jaws are ultrasonically tested before assembly. It has 50 mm ceramic-wool insulation, overpressure, overtemperature and vacuum protection, sensor-monitored and mechanical door locks, a Pilz safety relay and a patented door safety that keeps the door shut until pressure is fully released. It arrives on a single skid and runs once power and cooling water are connected; large-diameter units are built on site.

Composite autoclave
Composite autoclave 1Composite autoclave 2Composite autoclave 3Composite autoclave 4Composite autoclave 5
Benefits

Composite autoclave

  • ±1 °C temperature accuracy from turbulent front-to-back air circulation
  • Vacuum monitoring per bag, automatic leak tests and a 6-step pre-start check
  • Oil cooling with 3-way proportional valves (0.1 %) for a defined cooling curve
  • Pressurisation with air or nitrogen; the nitrogen can be recovered
  • Patented door safety; pressurisation starts only after the door locks confirm
  • Fatigue design for 25,000 cycles at maximum pressure
  • Recipe control and reporting; data exchange over Modbus, Modbus TCP/IP and PROFINET
  • No on-site COx, NOx or SOx emissions with electric heating
TSB Energy

Key specifications

SpecificationComposite Autoclave
Design pressure1 … 70 bar (per project)
Diameter≤ 5500 mm
Length≤ 61 m
Heat sourceElectricity · Thermal oil
Pressurisation gasAir or nitrogen
Temperature accuracy±1 °C
MaterialP355GH / P460NL (EN 10028-2)
Thermal insulation50 mm, ceramic wool (1260 °C, 128 kg/m³)
Design standardsPED 2014/68/EU · ASME VIII Div. 1 · EAC (GOST) · EN 13445 · AD 2000-Merkblatt

Let's choose the right product for your project together